CHN-650W-NRC-DG
Taoistic Solar
Aluminum/Steel
N-type TOPCon Technology, Half-cut cells
2382m x 1134mm x 30 mm
720pcs/40HQ Container
33.3Kg(Aluminum)
30years
| Availability: | |
|---|---|
Product Description
The 625W-650W bifacial solar panel uses N-type TOPCon cell technology and a dual-glass module structure for utility-scale, commercial and industrial photovoltaic projects.
Six power classes from 625W to 650W are available, with published module efficiency ranging from 23.2% to 24.1%. The module uses a 2382 × 1134 × 30mm format and weighs approximately 33.3kg.
The bifacial design allows the rear side of the module to utilize reflected irradiance where site conditions and mounting design provide suitable rear exposure.

| Parameter | 625W | 630W | 635W | 640W | 645W | 650W |
| Maximum Power Pmax | 625W | 630W | 635W | 640W | 645W | 650W |
| Maximum Power Voltage Vmp | 41.70V | 42.00V | 42.30V | 42.50V | 42.80V | 43.10V |
| Maximum Power Current Imp | 15.00A | 15.01A | 15.02A | 15.05A | 15.07A | 15.09A |
| Open-Circuit Voltage Voc | 49.90V | 50.20V | 50.50V | 50.80V | 51.10V | 51.40V |
| Short-Circuit Current Isc | 15.92A | 15.94A | 15.97A | 16.00A | 16.03A | 16.06A |
| Module Efficiency | 23.20% | 23.30% | 23.50% | 23.70% | 23.90% | 24.10% |
| Power Tolerance | 0 to +3W | |||||
| Temperature Coefficient of Isc | +0.046%/°C | |||||
| Temperature Coefficient of Voc | -0.250%/°C | |||||
| Temperature Coefficient of Pmax | -0.300%/°C | |||||
| Module Dimensions | 2382 × 1134 × 30mm | |||||
| Module Weight | 33.3kg | |||||
| Packaging | 36 Modules per Pallet / 720 Modules per Container | |||||
210R-N-16BB 625W-650W N-Type TOPCon Bifacial Solar Panel PDF
The product family covers six rated power classes from 625W to 650W, allowing project developers and EPC contractors to select an appropriate module bin for project design and procurement requirements.
The 650W model combines a published 43.10V maximum-power voltage with 15.09A maximum-power current under standard test conditions.
Final string sizing should use the electrical parameters of the exact ordered power class rather than applying one voltage and current value across the complete product family.
Published module efficiency increases from 23.2% for the 625W version to 24.1% for the 650W version.
Higher front-side power density can reduce the number of modules required to reach a target DC capacity where site layout, structural limits and electrical design permit.
Project energy yield should still be evaluated using local irradiation, module temperature, bifacial rear-side contribution, inverter configuration and other system losses.
The module uses a 210R N-type TOPCon cell platform with a multi-busbar cell interconnection design.
The rectangular-cell architecture enables high module power within a 1134mm module width that is commonly used across current utility and commercial photovoltaic module platforms.
The 625W-650W module uses a dual-glass bifacial structure with 2.0mm front glass and 2.0mm rear glass according to the current product information.
Front-side irradiance provides the rated STC power, while the transparent rear side allows usable reflected irradiance to contribute additional energy generation.
Actual bifacial energy gain depends on ground albedo, mounting height, row spacing, tilt angle, tracker configuration, rear-side shading and site irradiation.

The module measures 2382 × 1134 × 30mm and has a published weight of approximately 33.3kg.
The 2382mm × 1134mm format is used across a range of current high-power commercial and utility photovoltaic modules, making dimensions an important factor when evaluating trackers, mounting structures, clamps, transport and handling.
Final mounting compatibility should be checked against the supplied module drawing and approved clamping zones.
The current product information lists mechanical-load capability of up to 5400Pa on the front side and 2400Pa on the rear side.
The junction box is specified with an IP68 protection rating for outdoor photovoltaic applications.
Project engineers should verify the mounting configuration, clamp zones, support structure and site-specific wind and snow loads before installation.
The published operating-temperature range is -40°C to +85°C, with a nominal operating cell temperature of 44±2°C.
The specification lists a maximum-power temperature coefficient of -0.300%/°C, an open-circuit-voltage coefficient of -0.250%/°C and a short-circuit-current coefficient of +0.046%/°C.
These values should be used when evaluating expected module power and string voltage at different operating temperatures.

The current product information lists aluminum alloy and steel frame configurations for different photovoltaic project requirements.
| Selection Factor | Aluminum Alloy Frame | Steel Frame |
| Frame Type | Conventional photovoltaic aluminum-frame configuration. | Alternative steel-frame configuration for compatible projects. |
| Project Evaluation | Evaluate structural load, mounting compatibility and environmental conditions. | Evaluate coating specification, mounting system and environmental conditions. |
| Mounting | Confirm clamp position and mounting zones using the module drawing. | Confirm clamp position and mounting zones using the module drawing. |
| Availability | Confirm when requesting a quotation. | Confirm when requesting a quotation. |
The current specification lists 36 modules per pallet and 720 modules per container.
Final loading quantity should be reconfirmed before shipment because packing configuration can vary with frame option, packaging method and transport requirements.
The current product information describes a 12-year product warranty and a 30-year linear performance warranty.
Exact warranty duration, degradation limits, exclusions and applicable warranty documentation should be confirmed for the supplied module brand and sales contract.
The 625W-650W power range is suitable for evaluation in large ground-mounted photovoltaic projects where high module power and compatible mounting structures are required.
The 2382 × 1134mm module format can be evaluated for compatible tracker systems after the module dimensions, clamp zones, loading conditions and electrical characteristics have been checked.
High front-side module efficiency can support commercial and industrial projects where available installation area and target DC capacity make high-power modules appropriate.
The bifacial structure can be evaluated for elevated and ground-mounted installations where rear-side irradiance contributes to project energy yield.
Check the Voc, Vmp, Isc and Imp of the selected module power class against the inverter maximum DC voltage, MPPT operating range, maximum input current and maximum short-circuit-current limit.
Because module current reaches approximately 15A at maximum power and approximately 16A at short circuit, inverter input-current capability should be reviewed carefully during system design.
Cold-condition string Voc should also be calculated using the published voltage temperature coefficient and the minimum expected site temperature.
Rear-side energy contribution depends on the photovoltaic site and mounting system rather than being a fixed percentage for every installation.
Important design factors include ground reflectivity, module height, row spacing, tilt, tracker geometry, rear-side shading and surrounding structures.
Site-specific energy modeling should be used when expected bifacial gain materially affects project yield and financial calculations.
Get Project Configuration Support
The 625W-650W N-type TOPCon bifacial module is intended for professional photovoltaic procurement and project integration.
Buyers should provide the destination market, required power class, project type, inverter model, mounting system and required quantity when requesting a quotation.
Required frame option, connector type, cable length, certificates, warranty documents and packing configuration should also be confirmed before ordering.
Get Pricing & Technical Support
Available power classes are 625W, 630W, 635W, 640W, 645W and 650W.
The published maximum module efficiency is 24.1% for the 650W model.
Yes. The module uses an N-type TOPCon cell platform.
Yes. The dual-glass construction allows rear-side reflected irradiance to contribute to energy generation when the installation conditions provide sufficient rear exposure.
The published dimensions are 2382 × 1134 × 30mm.
The published module weight is approximately 33.3kg.
The 650W model has a published maximum-power current of 15.09A and short-circuit current of 16.06A.
The current specification table lists a positive power tolerance of 0 to +3W.
The published maximum-power temperature coefficient is -0.300%/°C.
The current product information lists up to 5400Pa front-side load and 2400Pa rear-side load.
The junction box is specified with IP68 protection.
Rear-side energy gain varies with ground albedo, mounting height, module spacing, tilt or tracker design, rear shading and site irradiation. It should not be treated as a fixed percentage for every project.
Yes, provided the module voltage and current characteristics are compatible with the inverter's MPPT range, maximum DC voltage, maximum input current and short-circuit-current limit.
The current product information lists both aluminum alloy and steel frame configurations. Final availability should be confirmed for the required order.
The current specification lists 36 modules per pallet and 720 modules per container. Final loading quantity should be confirmed before shipment.
The current product information describes a 12-year product warranty and a 30-year linear performance warranty. Exact warranty terms should be confirmed for the supplied module and contract.
Please provide the destination country, required wattage, project type, inverter model, mounting system, frame preference, documentation requirements and required quantity.

Product Category